Product model: | |
---|---|
Availability: | |
Quantity: | |
C7035
Honeywell
Honeywell C7027A - Integrated UV Flame Detector
C7027A1023 operating environment -18~102 ℃, lead length 2.4 meters
C7027A1031 operating environment -40~102 ℃, with a lead length of 2.4 meters
C7027A1049 operating environment -18~102 ℃, lead length 2.4 meters
C7027A1064 operating environment -40~102 ℃, lead length 7.3 meters
C7027A1072 operating environment -40~102 ℃, with a lead length of 2.4 meters
C7027A1080 operating environment -18~102 ℃, with a lead length of 2.4 meters
Replace old model with new model
C7027A1007 C7027A1080 1/2 6/72 0 to 215
C7027A1015 C7027A1031 1/2 6/72-40 to 215
C7027A1056 C7027A1056 1/2 8/96 0 to 215 DIN approved International model
C7027A1098 C7027A1098 a 1/2 8/96 0 to 215 Proprietary to Clear Brooks A
C7027A1106 C7027A1049 1/2 8/96 0 to 215 With 1/2 in. NPT connector
C7027A1114 C7027A1114 1/2 4.6/44 0 to 215 With 22 in. Flexible Conduit installed
C7044A1006 C7044A1006 Special Mounting6/72 0 to 215 Side Viewing International model
Honeywell C7035A - UV Flame Detector (replaceable UV detection tube) Outdoor Rain Protection, NEMA4
C7035A1023 operating environment -18~121 ℃, lead length 1.8 meters
C7035A1031 operating environment -40~121 ℃, lead length 1.8 meters
C7035A1056 operating environment -18~121 ℃, lead length 3.5 meters
C7035A1080 operating environment -18~121 ℃, lead length 1.8 meters
Replace the old model with the new model, matching Phototube/bulb
C7035A1007 C7035A1023 129464M 1 6/72 0 to 250
Honeywell C7027A - Integrated UV Flame Detector
C7027A1023 operating environment -18~102 ℃, lead length 2.4 meters
C7027A1031 operating environment -40~102 ℃, with a lead length of 2.4 meters
C7027A1049 operating environment -18~102 ℃, lead length 2.4 meters
C7027A1064 operating environment -40~102 ℃, lead length 7.3 meters
C7027A1072 operating environment -40~102 ℃, with a lead length of 2.4 meters
C7027A1080 operating environment -18~102 ℃, with a lead length of 2.4 meters
Replace old model with new model
C7027A1007 C7027A1080 1/2 6/72 0 to 215
C7027A1015 C7027A1031 1/2 6/72-40 to 215
C7027A1056 C7027A1056 1/2 8/96 0 to 215 DIN approved International model
C7027A1098 C7027A1098 a 1/2 8/96 0 to 215 Proprietary to Clear Brooks A
C7027A1106 C7027A1049 1/2 8/96 0 to 215 With 1/2 in. NPT connector
C7027A1114 C7027A1114 1/2 4.6/44 0 to 215 With 22 in. Flexible Conduit installed
C7044A1006 C7044A1006 Special Mounting6/72 0 to 215 Side Viewing International model
Honeywell C7035A - UV Flame Detector (replaceable UV detection tube) Outdoor Rain Protection, NEMA4
C7035A1023 operating environment -18~121 ℃, lead length 1.8 meters
C7035A1031 operating environment -40~121 ℃, lead length 1.8 meters
C7035A1056 operating environment -18~121 ℃, lead length 3.5 meters
C7035A1080 operating environment -18~121 ℃, lead length 1.8 meters
Replace the old model with the new model, matching Phototube/bulb
C7035A1007 C7035A1023 129464M 1 6/72 0 to 250